Dura Deck Aluminium’s high thermal conductivity dissipates heat, providing a cooler deck surface than most wood or composite surfaces. In live tests conducted on the hottest days of the year and in direct sunlight, Dura Deck Aluminium performed on average 18% better than the latest composite decks and was cooler underfoot by up to 13.8°C versus composite timber decking in a comparable colour. Dura Deck Aluminium features a unique surface powder coating that is specifically formulated and designed to make barefoot use a pleasure.

Aluminium vs. Composite Decking: Temperature Comparison in Sunlight at 31°C

Decking ColourDura Deck AluminiumDura Deck Composite TimberPercentage Difference
Anthracite52.5°C66.3°C-20.8%
Cedar50.5°C61.5°C-17.9%
Mist48.2°C57.5°C-16.2%
Background image

British Standards

NHBC BS 8579 Design of balconies and terraces with edge drainage

The National House Building Council, (NHBC) is the leading provider of warranties for new build housing in the UK. Each year, the NHBC releases an updated version of its technical standards after working with stakeholders from across the construction industry. As apartment developments with outdoor balcony spaces continue to rise in popularity, it is important to be familiar with the BS 8579 standard which sets a benchmark for quality of the design of balconies and terraces, and with the latest technical guidance from the NHBC.

Latest standards state that drainage is required on balconies where areas are 6m2 or over, and that consideration should also be given to providing drainage to areas that are less than 6m2, when considering factors such as exposure, where the water will end up, and potential adverse effects on the building or surrounding area.

British Standards

NHBC BS 8579 Design of balconies and terraces with edge drainage

The National House Building Council, (NHBC) is the leading provider of warranties for new build housing in the UK. Each year, the NHBC releases an updated version of its technical standards after working with stakeholders from across the construction industry. As apartment developments with outdoor balcony spaces continue to rise in popularity, it is important to be familiar with the BS 8579 standard which sets a benchmark for quality of the design of balconies and terraces, and with the latest technical guidance from the NHBC.

Latest standards state that drainage is required on balconies where areas are 6m2 or over, and that consideration should also be given to providing drainage to areas that are less than 6m2, when considering factors such as exposure, where the water will end up, and potential adverse effects on the building or surrounding area.

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

360° Colour Viewer

Explore our Aluminium Cladding and Decking Visualiser to create stunning, A2 fire-rated designs with Dura Cladding Aluminium and Dura Deck Aluminium. Perfect for safe, compliant balconies, terraces, and facades, this interactive tool helps you choose ideal colour pairings and visualise your project before sharing it with clients or colleagues.

Structural Requirements

Minimum load capacity of 5 kN/m² for pedestrian useDurable and corrosion-resistant materialsCompliance with testing protocols (e.g., BS 4592) for load capacity and deflection limits
Accessibility RequirementsAdherence to Disability Discrimination Act (DDA) and Access for All (AfA) guidelinesInclusion of tactile paving and high-contrast markingsNon-slip surfaces and minimum tread depths for safety

Structural Requirements

gdfgdfgd

Testing Beyond Limits: Our Credentials vs. Typical Other SuppliersDura CompositesTypical Other Supplier
A2fl s1 – Flooring Classification𐄂
A2s1,d0 – Other Building Products Classification𐄂
Tested by UKAS Accredited Facility𐄂
PPC Paint named, a requirement of UKAS to ensure continuity𐄂
Product specific tested and named in the certification𐄂
Product dimensions given that were physically tested𐄂
Product weights given that were physically tested𐄂
Airgap = 40mm and Greater (covers any build up depth 40mm & higher)𐄂
Can be mounted on any Substrate with density of 1350Kg/M3 with a minimum thickness of 6mm and fire performance of A2-s1,d0 or better𐄂
Tested in the Horizontal Plane, with joints permitted𐄂
UKAS Accredited Facilities are required to list all the above points and more in section 4.3 Field of application𐄂

Dura Deck Product Specifications

Dura Deck ProductMaterialLength (mm)Fire Rating (BS EN 13501)Span & LoadingWeight per L/M (kg)Weight per m² (kg)Surface FinishProduct Datasheet
Inspire 20mmPorcelain1800A1Up to 600mm Span based on 2kN Point Load (@5kN/UDL)7.7839WoodgrainView Datasheet
Free-Drain 18mmAluminium 6063 T63660A2fl-s1Up to 850mm Span based on 2kN Point Load (@5kN/UDL)1.268.40V-GrooveView Datasheet
Positive-Drain 18mmAluminium 6063 T65800A2fl-s1Up to 1050mm Span based on 2kN Point Load (@5kN/UDL)1.5110.05ReededView Datasheet
Positive-Drain 27mmAluminium 6063 T63600A2fl-s1Up to 1400mm Span based on 2kN Point Load (@5kN/UDL)2.0013.29ReededView Datasheet

Error: Contact form not found.